      Does Minimizing Ventricular Pacing Reduce the Incidence of Atrial Fibrillation? A Systematic Review and Meta-analysis of Randomized Controlled Trials

      review-article
      1 , , MS 2 , 3 , , MSc, MD 4 , , MD, FEHRA, FESC 4 , , MD, PhD 3 , , MD, PhD 5 , , MD, PhD 5 , , MD, FACC, FRCPC, FCCS 6 ,   , PhD, FESC, FACC, FSCAI, FHRS, FRCP 2 , 5 , 7 , , BSc 8 , , MD, PhD 2 , , , MD, PhD 7 , , International Health Informatics Study (IHIS) Network 1
      Cardiovascular Innovations and Applications
      Compuscript
      Atrial fibrillation, minimizing ventricular pacing, pacemaker
      Bookmark

            Abstract

            Background: Right ventricular pacing disrupts atrioventricular synchrony and increases the risk of atrial fibrillation (AF). However, whether algorithms for minimizing ventricular pacing reduce the incidence of AF remains controversial. Therefore, we conducted a systematic review and meta-analysis to compare the incidence of AF between minimizing ventricular pacing and conventional pacing protocols in patients with pacemakers implanted.

            Methods: The PubMed, Embase, and Cochrane Library databases were searched up to August 1, 2017, for randomized controlled trials that reported the incidence of AF in patients with and without the use of algorithms for minimizing ventricular pacing.

            Results: Eleven studies comprising 5705 participants (61% males, mean age 71 years [standard deviation 11 years]) were finally included in the analysis. The mean follow-up duration was 24 months. Use of algorithms for minimizing ventricular pacing significantly reduced the incidence of AF, with an odds ratio of 0.74 (95% confidence interval 0.55–1.00; P<0.05). There was moderate heterogeneity among studies (I 2=63%).

            Conclusions: The incidence of AF was reduced by 26% with use of algorithms for minimizing ventricular pacing. The incorporation of such algorithms in routine clinical practice should in theory lead to a decrease in AF-related morbidity and mortality.

            Main article text

            Significance Statement: Right ventricular pacing disrupts atrioventricular synchrony and increases the risk of atrial fibrillation (AF). Whether algorithms for minimizing ventricular pacing reduce the incidence of AF remains controversial. This systematic review and meta-analysis demonstrates that minimizing ventricular pacing significantly reduced the incidence of AF, with an odds ratio of 0.74. This has important implications for the long-term prognosis of these patients.

            Introduction

            Pacemaker implantation is indicated in bradyarrhythmias, including sinus node dysfunction, bifascicular block, trifascicular block, and atrioventricular (AV) block [1]. Standard ventricular pacing is normally performed from the right ventricular (RV) apex, owing to the long-term stability this position offers and the ease with which it can be accessed for lead placement. Many recently conducted clinical studies have illustrated that RV pacing is associated with an increase in the risk of atrial fibrillation (AF), among other adverse effects [2]. Conventional RV pacing disrupts the ventricular synchrony that is observed in a normal heart. This may lead to mitral insufficiency, left atrial enlargement, and left ventricular (LV) hypertrophy, which collectively predispose to AF [3].

            A contemporary approach to circumvent the detrimental effects associated with RV pacing is the incorporation of pacing algorithms in dual-chamber pacemakers. These algorithms focus on preserving physiological ventricular activation as much as possible, with periodic changes in pacing mode and/or timing cycles in an attempt to minimize ventricular pacing [4]. However, whether minimizing ventricular pacing actually decreases the incidence of AF remains controversial. While certain randomized controlled trials (RCTs) have demonstrated that minimizing ventricular pacing, mediated by novel pacing algorithms, is associated with a reduction in AF incidence [59], others have shown no such correlation [2, 1014]. Therefore, we conducted a systematic review and meta-analysis of RCTs with the aim of comparing the incidence of AF between minimizing ventricular pacing and conventional pacing protocols in patients with permanent pacemakers.

            Methods

            Search Strategy, Inclusion Criteria, and Quality Analysis

            This systematic review and meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement [15]. It has been registered with PROSPERO. PubMed, Embase, and the Cochrane Library were searched up to August 1, 2017, with no language restriction, for studies that investigated the incidence of AF with and without minimizing ventricular pacing. The following search terms were used: [“minimizing right ventricular pacing” or “managed ventricular pacing” or “minimize ventricular pacing” or “ventricular pacing reduction”]. The following inclusion criteria were applied: (1) the design of the study was an RCT in humans; (2) AF incidence was reported for minimizing ventricular pacing and nonminimizing ventricular pacing modes. Quality assessment of RCTs was performed with the Cochrane Collaboration’s tool (Supplementary Figures 1 and 2) [16].

            Data Extraction and Statistics

            Data from the different studies were entered in a prespecified spreadsheet in Microsoft Excel. All potentially relevant reports were retrieved as complete articles and assessed for compliance with the inclusion criteria. In this meta-analysis, the extracted data elements consisted of (1) publication details (last name of first author, publication year, and location); (2) the follow-up duration; (3) the end points; (4) the quality score; and (5) the characteristics of the population, including sample size, sex, age, and number of participants. Two reviewers (I.L. and M.G.) independently reviewed each included study, and disagreements were resolved by adjudication with input from a third reviewer (G.T.). The end point for this meta-analysis was incident AF. Event rates for AF were extracted for each study. This enabled the calculation of odds ratios, which were then pooled in the meta-analysis.

            Heterogeneity between studies was determined with Cochran’s Q, which is the weighted sum of squared differences between individual study effects and the pooled effect across studies, and the I 2 statistic from the standard chi-square test, which is the percentage of the variability in effect estimates resulting from heterogeneity. I 2>50% was considered to reflect significant statistical heterogeneity. A fixed-effects model was used if I 2<50%; otherwise the random-effects model using the inverse variance heterogeneity method was selected. To locate the origin of the heterogeneity, sensitivity analysis excluding one study at a time was performed. Funnel plots, the Begg and Mazumdar rank correlation test, and Egger’s test were used to detect possible publication bias.

            Results

            Figure 1 shows a flow diagram detailing the search strategy and study selection process. In total, 215 publications were retrieved from PubMed and 115 were retrieved from Embase. A total of 11 studies involving 5705 patients (mean age 71 years [standard deviation 11 years], 61% males) were included. The baseline characteristics of these studies are listed in Table 1. The mean follow-up duration was 24 months. Our meta-analysis shows that use of algorithms for minimizing ventricular pacing significantly reduced the odds of developing AF (odds ratio 0.74; 95% confidence interval 0.55–1.00; P<0.05; Figure 2). Cochran’s Q was greater than the number of degrees of freedom (27 vs. 10), suggesting the true effect size was different among the various studies. Moreover, I 2 was 63%, indicating the presence of moderate heterogeneity. This was potentially due to variations in study protocols, ranging from differences in sample sizes and follow-up periods to the definitions of incident AF used. Sensitivity analysis by a leave-one-out study did not significantly alter the pooled odds ratio (Supplementary Figure 3). Funnel plots plotting standard error or precision against the logarithm of the odds ratio are shown in Supplementary Figures 4 and 5, respectively. Begg and Mazumdar rank correlation suggested no significant publication bias (Kendal’s τ was −0.2; P>0.05). Egger’s test demonstrated no significant asymmetry (intercept−0.8, t=0.5; P>0.05).

            Figure 1:

            Flow Diagram Detailing the Search Strategy and Study Selection Process for This Systematic Review and Meta-Analysis of the Effects of Minimizing Ventricular Pacing in Reducing the Incidence of Atrial Fibrillation (AF).

            Figure 2:

            Odds Ratios for Included Studies Examining the Effects of Minimizing Ventricular Pacing Algorithms on the Incidence of Atrial Fibrillation.

            Meta-analysis of 11 randomized controlled trials revealed that the use of algorithms for minimizing ventricular pacing significantly reduced the odds of developing atrial fibrillation. CI, confidence interval.

            Table 1

            Characteristics of the Studies Included in This Meta-Analysis.

            StudySample size (n)Algorithm for minimizing ventricular pacing (n)Controls (n)Average age (years)No. of malesName of trialComparisonAF definitionFollow-up duration (months)
            Sweeney et al. [10]103051851262818MVPManaged ventricular pacing vs. VVIPersistent AF29
            Pakarinen and Toivonen [11]38919519473180VIP on vs. VIP offAF12
            Boriani et al. [5]76838338574583MINERVADDDRP + managed ventricular pacing vs. DDDRPPermanent AF24
            Botto et al. [12]60529930675365Prefer for Elective Replacement Managed Ventricular PacingManaged ventricular pacing + DDD vs. DDDPersistent AF24
            Davy et al. [13]42214128173211SafeR vs. DDDPermanent AF12
            Gillis et al. [2]2581291297298Managed ventricular pacing vs. DDDRPAt least one episode of AT/AF6
            Malliet et al. [17]974948SafeR vs. DDDAF35
            Stockburger et al. [6]63231431872358ANSWERSafeR vs. DDDAF36
            Sweeney et al. [7]106553053572520SAVE PACeDual-chamber minimal ventricular pacing vs. conventional dual-chamber pacingPersistent AF20
            Thibault et al. [8]37319118271233CAN-SAVE RSafeR vs. DDDAF36
            Veasey et al. [9]6633337537MinVPACEManaged ventricular pacing vs. DDDRPAF17

            Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP). AF, atrial fibrillation; AT, atrial tachycardia; DDD: dual-chamber pacing; VVI, backup-only ventricular pacing.

            Discussion

            This study was a systematic review and meta-analysis of 11 RCTs evaluating the effects of minimizing ventricular pacing on the incidence of AF in 5705 patients. The main finding was a 26% reduction in the risk of incident AF with use of algorithms for minimizing ventricular pacing compared with no use.

            Electrical activation of the heart typically occurs through the cardiac conduction system. Many defects that may manifest themselves in this normal pathway are treated by pacemaker implantation, involving the RV apex. Pacing of the right ventricle is nonphysiological, and provides a route through which the depolarization wave can circumvent the standard pattern of myocardial activation. As such, this leads to delayed stimulation of the left ventricle akin to that in left bundle branch block [18], in turn culminating in ventricular dyssynchrony, along with an increased risk of mitral insufficiency, left atrial enlargement, and LV hypertrophy, all of which collectively induce AF [3]. The underlying pathophysiological mechanisms consist of atrial structural remodeling via fibrosis: an electrophysiological substrate that predisposes to arrhythmogenesis by reducing the conduction velocity of action potentials propagating through the atria [19]. The necessity of pacing for patients with bradyarrhythmias coupled with its evident indirect role in AF pathogenesis presents a clinical dilemma, wherein artificial stimulation needs to be delivered at just the optimal dosage so as to maximize treatment while preventing the development of detrimental atrial arrythmias.

            Conventional dual-chamber pacemaker strategies, albeit effective in sustaining AV synchrony, involve higher incidences of pacing that, as already mentioned, limit therapeutic benefit by enhancing ventricular dysfunction [20]. One solution proposed to overcome this problem is the use of alternative pacing sites instead of the RV apex, aiming to conduct the electrical wavefront in a more physiological manner throughout the heart [21]. The primary anatomical locations that have been investigated include the RV outflow tract, the intraventricular septum, and the bundle of His. Although some evidence suggests the superiority of such sites over apical pacing in terms of dyssynchrony burden as well as LV function and structure [22, 23], there are also data supporting the contrary [24]. More recently, however, the advent of algorithms for minimizing ventricular pacing provides another possible answer to the issue of unwanted, excessive pacing. These algorithms accomplish this by prolonging the AV interval such that intrinsic AV conduction, if present, is maintained and ventricular stimulation, in turn, is delivered only in the absence of an AV impulse within the elongated period [25]. The feasibility of these algorithms has been heavily scrutinized with the conduction of many RCTs intending to examine the effect of different ventricular pacing reduction modalities compared with conventional dual-chamber pacing on the incidence of AF. A meta-analysis of the data from seven such RCTs failed to demonstrate a significant difference in the occurrence of new-onset AF in these two groups [26]. However, this investigation excluded certain trials because of their crossover study design, leading to exclusion of some key cohorts. In contrast, our meta-analysis included data from four additional trials, with the pooled-effect estimate showing a significant benefit in minimizing ventricular pacing for reducing incident AF. Given this apparent therapeutic advantage, together with its additional benefits, such as increasing device longevity and reducing the need for device replacement and its subsequent complications, the incorporation of algorithms for minimizing ventricular pacing in routine clinical practice should in theory lead to a decrease in AF-related morbidity and mortality.

            Conflicts of Interest

            The authors declare that they have no conflicts of interest.

            Funding and Acknowledgment

            G.T. thanks the Croucher Foundation of Hong Kong for his clinical assistant professorship.

            References

            1. GregoratosG, CheitlinMD, ConillA, EpsteinAE, FellowsC, FergusonTB, et al. ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: executive summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). Circulation 1998;97(13):1325–35.

            2. GillisAM, PürerfellnerH, IsraelCW, SunthornH, KacetS, Anelli-MontiM, et al. Reducing unnecessary right ventricular pacing with the managed ventricular pacing mode in patients with sinus node disease and AV block. Pacing Clin Electrophysiol 2006;29(7):697–705.

            3. YadavR, JaswalA, ChennapragadaS, KamathP, HiremathSMS, KahaliD, et al. Effectiveness of Ventricular Intrinsic Preference (VIP) and Ventricular AutoCapture (VAC) algorithms in pacemaker patients: results of the validate study. J Arrhythm 2016;32(1):29–35.

            4. MurakamiY, TsuboiN, IndenY, YoshidaY, MuroharaT, IharaZ, et al. Difference in percentage of ventricular pacing between two algorithms for minimizing ventricular pacing: results of the IDEAL RVP (Identify the Best Algorithm for Reducing Unnecessary Right Ventricular Pacing) study. Europace 2010;12(1):96–102.

            5. BorianiG, TukkieR, ManolisAS, MontL, PürerfellnerH, SantiniM, et al. Atrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trial. Eur Heart J 2014;35(35):2352–62.

            6. StockburgerM, BovedaS, MorenoJ, Da CostaA, HatalaR, BrachmannJ, et al. Long-term clinical effects of ventricular pacing reduction with a changeover mode to minimize ventricular pacing in a general pacemaker population. Eur Heart J 2015;36(3):151–7.

            7. SweeneyMO, BankAJ, NsahE, KoullickM, ZengQC, HettrickD, et al. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med 2007;357(10):1000–8.

            8. ThibaultB, DucharmeA, BaranchukA, DubucM, DyrdaK, GuerraPG, et al. Very low ventricular pacing rates can be achieved safely in a heterogeneous pacemaker population and provide clinical benefits: the CANadian Multi-Centre Randomised Study-Spontaneous AtrioVEntricular Conduction pReservation (CAN-SAVE R) trial. J Am Heart Assoc 2015;4(7):e001983.

            9. VeaseyRA, AryaA, SilberbauerJ, SharmaV, LloydGW, PatelNR, et al. The relationship between right ventricular pacing and atrial fibrillation burden and disease progression in patients with paroxysmal atrial fibrillation: the long-MinVPACE study. Europace 2011;13(6):815–20.

            10. SweeneyMO, EllenbogenKA, TangAS, WhellanD, MortensenPT, GiraldiF, et al. Atrial pacing or ventricular backup-only pacing in implantable cardioverter-defibrillator patients. Heart Rhythm 2010;7(11):1552–60.

            11. PakarinenS, ToivonenL. Minimizing ventricular pacing by a novel atrioventricular (AV) delay hysteresis algorithm in patients with intact or compromised intrinsic AV conduction and different atrial and ventricular lead locations. Ann Med 2013;45(5–6):438–45.

            12. BottoGL, RicciRP, BénézetJM, NielsenJC, De RoyL, PiotO, et al. Managed ventricular pacing compared with conventional dual-chamber pacing for elective replacement in chronically paced patients: results of the Prefer for Elective Replacement Managed Ventricular Pacing randomized study. Heart Rhythm 2014;11(6):992–1000.

            13. DavyJM, HoffmannE, FreyA, JochamK, RossiS, DupuisJ-M, et al. Near elimination of ventricular pacing in SafeR mode compared to DDD modes: a randomized study of 422 patients. Pacing Clin Electrophysiol 2012;35(4):392–402.

            14. StockburgerM, DefayeP, BovedaS, StancakB, LazarusA, SipötzJ, et al. Safety and efficiency of ventricular pacing prevention with an AAI-DDD changeover mode in patients with sinus node disease or atrioventricular block: impact on battery longevity-a sub-study of the ANSWER trial. Europace 2016;18(5):739–46.

            15. MoherD, ShamseerL, ClarkeM, GhersiD, LiberatiA, PetticrewM, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Syst Rev 2015;4:1.

            16. HigginsJP, AltmanDG, GøtzschePC, JüniP, MoherD, OxmanAD, et al. The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. Br Med J 2011;343:d5928.

            17. MallietN, TalajicM, RoyD, DubucM, KhairyP, MacleL, et al. Minimizing unnecessary ventricular pacing with AAI-DDD pacing mode does not prevent atrial fibrillation compared to DDD pacing with long AV delay: insights from long-term follow-up of CAN-SAVER study patients. Heart Rhythm 2014. 11(5) Supplement 2014, Article PO02-51.

            18. EbrilleE, DeSimoneCV, VaidyaVR, ChahalAA, NkomoVT, AsirvathamSJ. Ventricular pacing – electromechanical consequences and valvular function. Indian Pacing Electrophysiol J. 2016;16(1):19–30.

            19. ChoyL, YeoJM, TseV, ChanSP, TseG. Cardiac disease and arrhythmogenesis: Mechanistic insights from mouse models. Int J Cardiol Heart Vasc. 2016;12:1–10.

            20. KossaifyA, ZoghbiS, MilliezP. Assessment of ventricular pacing in the setting of an institutional improvement program: insights into physiological pacing. Clin Med Insights Cardiol. 2012;6:79–85.

            21. ŁuciukD, ŁuciukM, GajekJ. Alternative right ventricular pacing sites. Adv Clin Exp Med 2015;24(2):349–59.

            22. LeongDP, MitchellAM, SalnaI, BrooksAG, SharmaG, LimHS, et al. Long-term mechanical consequences of permanent right ventricular pacing: effect of pacing site. J Cardiovasc Electrophysiol 2010;21(10):1120–6.

            23. CatanzaritiD, MainesM, CeminC, BrosoG, MarottaT, VergaraG. Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing. An intrapatient acute comparison study. J Interv Card Electrophysiol. 2006;16(2):81–92.

            24. ShimonyA, EisenbergMJ, FilionKB, AmitG. Beneficial effects of right ventricular non-apical vs. apical pacing: a systematic review and meta-analysis of randomized-controlled trials. Europace 2012;14(1):81–91.

            25. AkerströmF, AriasMA, PachónM, Jiménez-LópezJ, PucholA, Juliá-CalvoJ. The importance of avoiding unnecessary right ventricular pacing in clinical practice. World J Cardiol 2013;5(11):410–9.

            26. ShurrabM, HealeyJS, Haj-YahiaS, KaoutskaiaA, BorianiG, CarrizoA, et al. Reduction in unnecessary ventricular pacing fails to affect hard clinical outcomes in patients with preserved left ventricular function: a meta-analysis. Europace 2017;19(2):282–8.

            Supplemental Material:

            The online version of this article (DOI: 10.15212/CVIA.2019.0586) offers supplementary material, available to authorized users at the following link: https://cvia-journal.org/wp-content/uploads/2020/09/Supplementary-Does-Minimizing-Ventricular-Pacing-Reduce-the-1.pdf.

            Author and article information

            Journal
            CVIA
            Cardiovascular Innovations and Applications
            CVIA
            Compuscript (Ireland )
            2009-8782
            2009-8618
            September 2020
            September 2020
            : 5
            : 1
            : 1-7
            Affiliations
            [1] 1Laboratory of Cardiovascular Physiology, Li Ka Shing Institute of Health Sciences, Hong Kong Special Administrative Region, People’s Republic of China
            [2] 2Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, People’s Republic of China
            [3] 3Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, Special Administrative Region, People’s Republic of China
            [4] 4Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Athens, Greece
            [5] 5Department of Cardiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
            [6] 6Division of Cardiology, Kingston General Hospital, Queen’s University, Kingston, Ontario, Canada
            [7] 7Xiamen Cardiovascular Hospital, Xiamen University, Xiamen, Fujian, People’s Republic of China
            [8] 8Aston Medical School, Aston University, Birmingham, United Kingdom
            Author notes
            Correspondence: Dong Chang, MD, PhD, Xiamen Cardiovascular Hospital, Xiamen University, Xiamen, Fujian, People’s Republic of China, E-mail: cdheart@ 123456126.com ; and Tong Liu, MD, PhD, Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, People’s Republic of China, E-mail: liutongdoc@ 123456126.com
            Article
            cvia.2019.0586
            10.15212/CVIA.2019.0586
            824b1c58-7001-409e-ad56-9e31f00f595d
            Copyright © 2020 Cardiovascular Innovations and Applications

            This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 Unported License (CC BY-NC 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc/4.0/.

            History
            : 12 November 2019
            : 13 August 2020
            : 21 August 2020
            Categories
            Review

            General medicine,Medicine,Geriatric medicine,Transplantation,Cardiovascular Medicine,Anesthesiology & Pain management
            pacemaker,Atrial fibrillation,minimizing ventricular pacing